Image
Specifications
Gorter® - completely assembled:
- Frame ≤ 1250 mm: channel type in anodized aluminium
- Frame > 1251 mm: channel type in KTL (cathodic dip painting) treated steel
- Lid: pan type in anodized aluminium, recess 25 mm, available with wire mesh
- For tiles or carpet
- Prepared with thread for u-PVC drainage coupling 40 mm (without coupling)
Standard dimensions - weight:
600 x 600 mm / 24 kg
800 x 800 mm / 30 kg
1000 x 1000 mm / 48 kg
1000 x 1500 mm / 103 kg
1000 x 2000 mm / 125 kg
Longest side is hinge side
Special dimensions (mm):
........ x ........ mm
Load:
7,5 kN/m2 (according to EN1991)
Hardware:
- Counterbalancing system for assisted opening and controlled closing
- Hinges
- Hold-open arm that engages automatically
- Snap latch with T-key and removable watertight plug on top cover
- Option: padlock hasps
Installation:
Welded strap anchors
Options
Gorter® - Electrical Operation of Roof Hatches and Floor Doors
Standard Electrical operation - GT35
The Gorter GT35 electrical operation is a solution, which can be fitted on floor door of the type WA, WAPT and OP. The two powerful electric motors are always fitted as a pair on both sides of the lid.
Suitable for
- Hinged Floor doors type WA (flush), WAPT and OP
Operation and control 230Vac
The Gorter GT35 is a system with two motors and a control unit. The system comes standard with a wireless remote control and a compact control panel. The keypad connected with signal cable can be installed remote from control unit.
Dimensions:
Control unit: 265 x 105 x 40 mm
Keypad: +/- 70 x 50 x 10 mm
Length of signal/power cable motors: 2 m
Electrical installation:
The drives and the wiring must be installed by a certified installer
Operation for a hatch with double lids
Depending on the access door type, the weight of the cover and the application, we can install one or more gear rack drives. These drives are available in 24 Vdc or 230 Vac.
Operation and control 230Vac
This is the simplest system with 1 motor. It can be operated with an integrated or surface-mounted switch, not included.
Operation and control 24Vdc
Operation of one or more drives is controlled by a control box with rectifier that is connected to the electricity network.
Features
- Communication with central alarm system, possibly combined with emergency switch
- Programmable
- Operation control of other objects
- Control by automatic detectors - smoke, rain, wind, fire etc.
- Automatic sequence control of two covers that are overlapping
- Automatic stop in case of unequal load or overload
- etc.
Depending on the features we will recommend a suitable control box type.
Emergency hatches and doors:
It is of life importance that an emergency door opens after a break down of the electrical system. For those reasons a control box can be provided with a built-in emergency power pack.
Electrical installation:
The drives and the wiring must be installed by a certified installer.
Downloads
Documentation:
Overview brochure1.93 MB
Technical Data Sheet - Reset / Calibration GT35 / GT50202.93 KB
WAPT declaration of performance 266.19 KB
Manuals:
User information floor door hinged2.12 MB
Certificates:
Codemark® Certificate of Conformity479.79 KB
Drawings:
Acrobat |
AutoCAD .dwg |
Sketchup .skp |
REVIT .rfa |
REVIT
.rvt |
REVIT
.ifc |
|
WAPT-600-600 | |
|||||
WAPT-800-800 | ||||||
WAPT-1000-1000 | ||||||
WAPT-1000-1500 | ||||||
WAPT-1000-2000 | ||||||
WAPTD |
Watch the Revit instruction video
Quote
The Gorter WAPT hinged floor door provides practical and safe access to the areas below. The pan-type cover is suitable for pouring cement followed by tiling or the laying of floor covering (carpet, laminate, etc.).
Inside and outside use - for concrete floors, tiles and floor coverings
The reinforcing mesh supplied is placed in the cover when pouring cement. The cover is made of anodised aluminium, and the hatch is suitable for both inside and outside use. The powder-coated steel frame has an optional connection for a drainage system / rain water discharge.
Sizes
The Gorter hinged aluminium floor door with recessed cover is available in five standard sizes as well as special sizes.
Combination with ladders and stairs
Depending on the size and application, WAPT floor doors can be combined with a Gorter an extension ladder. A scissor stair can be used in some cases.
Usage
Hinged floor doors are not recommended in situations subject to dynamic loads. The floor door is optionally available to support loadings specified by the customer.
Gorter hinged, aluminium, recessed, floor door:
- For inside and outside use
- In standard and special sizes
- Safe to operate with one hand
- The counter-balance system helps with opening and slows closing
- Automatic locking in open position and unlocking with one hand
- Door catch with removable crank and watertight plug on top side
- Safe handle on inside of cover (opening length > 1,000 mm)
- 5-year warranty on the floor door
- High-quality construction
- Rain water drain connection using 40 mm ø PVC sleeve (excl. sleeve)
- Reinforcing mesh supplied for pouring cement