Certifications:
CE ETA-15/0338
Aboma certificate
TÜV NORD certified according to EN 14975:2010, with label ''Baumuster geprüft"
Roof hatch, type RHT7014
Standard opening size: 700 x 1400 mm (Hinge side = long side)
Weight: 68 kg
Gorter® - completely assembled with:
Performance according to CE (ETA-15/0338):
Insulating (EN-ISO10077-2): Uw ≤ 0.32 W/(m².K)
RHT powder coating:
Outside: powder coated in RAL7047
Inside: powder coated in white RAL 9010 (optional black RAL9004)
Scissor stair, type EI 60 - fire rated
KOMO:SKG.0372.0457
Fire rating classification: EI-60 according to EN 1634-1
Casing:
Ceiling height: ........ mm, standard 3000 mm.
to be specified from top of floor to bottom of cover.
Option: up to 3500 mm (type Large-H EI-60).
Stair:
Projection while opening:
Max. 700 mm at ceiling height 3000 mm (type Large EI-60)
Max. 950 mm at ceiling height 3500 mm (type Large-H EI-60)
Hardware:
Extension of scissor stair in plenum (option):
The stair can be extended to bridge the distance between ceiling and roof hatch in cases where it is mounted in a suspended ceiling/plenum
Standard Electrical operation - GT35
The Gorter GT35 electrical operation is a solution, which can be fitted on any standard Gorter RHT roof hatch. The two powerful electric motors are always fitted as a pair on both sides of the lid.
Suitable for
Operation and control 230Vac
The Gorter GT35 is a system with two motors and a control unit. The system comes standard with a wireless remote control and a compact control panel. The keypad connected with signal cable can be installed remote from control unit.
Dimensions:
Control unit: 265 x 105 x 40 mm
Keypad: +/- 70 x 50 x 10 mm
Length of signal/power cable motors: 2 m
Electrical installation:
The drives and the wiring must be installed by a certified installer
Operation for a hatch with double lids
Depending on the access door type, the weight of the cover and the application, we can install one or more gear rack drives. These drives are available in 24 Vdc or 230 Vac.
Operation and control 230Vac
This is the simplest system with 1 motor. It can be operated with an integrated or surface-mounted switch, not included.
Operation and control 24Vdc
Operation of one or more drives is controlled by a control box with rectifier that is connected to the electricity network.
Features
Depending on the features we will recommend a suitable control box type.
Emergency hatches and doors:
It is of life importance that an emergency door opens after a break down of the electrical system. For those reasons a control box can be provided with a built-in emergency power pack.
Electrical installation:
The drives and the wiring must be installed by a certified installer.
Documentation:
Roof hatch RHT brochure2.71 MB
Technical Data Sheet - Roof Hatches RHT / RHTEI / RHTX154.82 KB
Technical Data Sheet - Scissor stair116.96 KB
Technical Data Sheet - extension of Scissor stair224.99 KB
Technical Data Sheet - Reset / Calibration GT35 / GT50202.93 KB
Manuals:
User information roof hatches2.30 MB
User information scissor stairs3.30 MB
Drawings:
Acrobat |
AutoCAD .dwg |
Sketchup .skp |
REVIT .rfa |
REVIT
.rvt |
REVIT
.ifc |
|
RHT7014 |
Watch the Revit instruction video
Acrobat |
AutoCAD .dwg |
Sketchup .skp |
REVIT .rfa |
REVIT
.rvt |
REVIT
.ifc |
|
Large EI-60 700 x 1200 mm |
||||||
Large-H EI-60 700 x 1200 mm |
Watch the Revit instruction video
Installation roof hatch on concrete upstand42.61 KB
Installation roof hatch on concrete or steel roof45.29 KB
Installation roof hatch on concrete roof41.13 KB
Installation roof hatch on concrete roof insulated53.77 KB
Certificates:
Declaration of performance CE roof hatch RHT44.71 KB
TÜV NORD Certificate: Roof hatch with ladder, scissor stairs and fixed stairs413.16 KB
TÜV NORD Certificate: Scissor stairs240.38 KB
KOMO Certificate: Roof hatch RHT120.07 KB
KOMO Certificate: EI-60 fire-resistant hatch constructions with or without scissor stairs211.01 KB
Aboma Certificate: Roof hatch with scissor stairs70.66 KB
Certificate fire rated scissor stairs EI60168.59 KB
EuroSolid Report: Thermal performance Roof hatch RHT525.05 KB
Peutz Report: Sound insulation roof hatch RHT1.14 MB
Gorter roof hatches with scissor stairs provide practical and safe access to flat roofs for maintenance work or other purposes. The roof hatch can be installed on flat roofs with a maximum pitch of 30°.
The Gorter combination of roof hatch and Large fireproof scissor stair provides generous access to the roof and is available for ceiling heights of max. 3,000. The roof hatch has an opening of 700 x 1,400 mm.
In this combination, the scissor stair is fire-resistant, with an EI-60 class. The roof hatch is a standard Gorter RHT7014 roof hatch. If a higher fire class is required, Gorter can also supply fully fire-resistant roof hatch with an EI120 class.
Roof hatches combined with a scissor stair are ideal for applications where occasional but also frequent access to the roof is required. When the scissor stair is folded, you always have free space under the hatch.
The new generation RHT roof hatches feature an extremely strong and patented construction. Thanks to several modifications, the roof hatch is even more resistant against unexpected extreme loads, both during construction and in general use.
Improved features and functionalities of the indestructible and sustainable RHT roof hatch:
The Gorter RHT roof hatch has a fully thermally broken curb and cover, and a proven high insulation value of Uw ≤ 0.319 W/(m².K) This minimises the chance of condensation forming and guarantees energy cost savings.
10-year warranty on the roof hatch, 1 year on climbing devices
Read more about the advantages of Gorter roof hatches here
Certifications:
CE ETA-15/0338
Aboma certificate
TÜV NORD certified according to EN 14975:2010, with label ''Baumuster geprüft"
Roof hatch, type RHT7014
Standard opening size: 700 x 1400 mm (Hinge side = long side)
Weight: 68 kg
Gorter® - completely assembled with:
Performance according to CE (ETA-15/0338):
RHT powder coating:
Outside: powder coated in RAL7047
Inside: powder coated in white RAL 9010 (optional black RAL9004)
Scissor stair, type Large
Casing:
Ceiling height: ........ mm, standard 3000 mm.
to be specified from top of floor to bottom of cover.
Option: up to 3500 mm (type Large-H)
Stair:
Projection while opening:
Max. 700 mm at ceiling height 3000 mm (type Large)
Max. 950 mm at ceiling height 3500 mm (type Large-H)
Hardware:
Extension of scissor stair in plenum (option):
The stair can be extended to bridge the distance between ceiling and roof hatch in cases where it is mounted in a suspended ceiling / plenum
Standard Electrical operation - GT35
The Gorter GT35 electrical operation is a solution, which can be fitted on any standard Gorter RHT roof hatch. The two powerful electric motors are always fitted as a pair on both sides of the lid.
Suitable for
Operation and control 230Vac
The Gorter GT35 is a system with two motors and a control unit. The system comes standard with a wireless remote control and a compact control panel. The keypad connected with signal cable can be installed remote from control unit.
Dimensions:
Control unit: 265 x 105 x 40 mm
Keypad: +/- 70 x 50 x 10 mm
Length of signal/power cable motors: 2 m
Electrical installation:
The drives and the wiring must be installed by a certified installer
Operation for a hatch with double lids
Depending on the access door type, the weight of the cover and the application, we can install one or more gear rack drives. These drives are available in 24 Vdc or 230 Vac.
Operation and control 230Vac
This is the simplest system with 1 motor. It can be operated with an integrated or surface-mounted switch, not included.
Operation and control 24Vdc
Operation of one or more drives is controlled by a control box with rectifier that is connected to the electricity network.
Features
Depending on the features we will recommend a suitable control box type.
Emergency hatches and doors:
It is of life importance that an emergency door opens after a break down of the electrical system. For those reasons a control box can be provided with a built-in emergency power pack.
Electrical installation:
The drives and the wiring must be installed by a certified installer.
Extension of types Large and XL
Safety Approval Report(EN-ISO 14122-3) available
Height: ........mm
to be specified from ceiling to roof hatch flange or roof deck.
Stairs:
Material: aluminium
Steps are anti-skid
Size steps: 360 x 140 x 26 mm (types Large)
Size steps: 480 x 140 x 26 mm (type XL)
Steps can be horizontally adjusted
Hardware:
Brackets
More information? Please click Products > Ladders and stairs > Extension of scissor stairs - attic ladder
Technical Data Sheet - Roof Hatches RHT / RHTEI / RHTX154.82 KB
Technical Data Sheet - Scissor stair116.96 KB
Technical Data Sheet - Extension of Scissor stair224.99 KB
Technical Data Sheet - Reset / Calibration GT35 / GT50202.93 KB
Manuals:
User information roof hatches2.30 MB
User information scissor stairs3.30 MB
Drawings:
Acrobat |
AutoCAD .dwg |
Sketchup .skp |
REVIT .rfa |
REVIT
.rvt |
REVIT
.ifc |
|
RHT7014 |
Watch the Revit instruction video
Acrobat |
AutoCAD .dwg |
Sketchup .skp |
REVIT .rfa |
REVIT
.rvt |
REVIT
.ifc |
|
Large 700 x 1200 mm |
||||||
Large-H 700 x 1200 mm |
Watch the Revit instruction video
Drawing roof hatch RHT7014254.87 KB
Installation roof hatch on concrete upstand42.61 KB
Installation roof hatch on concrete or steel roof45.29 KB
Installation roof hatch on concrete roof41.13 KB
Installation roof hatch on concrete roof insulated53.77 KB
Certificates:
Declaration of performance CE roof hatch RHT44.71 KB
KOMO Certificate: Roof hatch RHT120.07 KB
TÜV NORD Certificate: Roof hatch with ladder, scissor stairs and fixed stairs413.16 KB
TÜV NORD Certificate: Scissor stairs240.38 KB
Aboma Certificate: Roof hatch with scissor stairs70.66 KB
EuroSolid Report: Thermal performance Roof hatch RHT525.05 KB
Peutz Report: Sound insulation roof hatch RHT1.14 MB
{rsformgt 40 products='Roof hatch',roof-hatches='RHT',ladders-and-stairs='Scissor stairs',type-scissor-stairs='Standard',scissor-stairs='RHT7014: 700 x 1400 mm'}
Gorter roof hatches with scissor stairs provide practical and safe access to flat roofs for maintenance work or other purposes. The roof hatch can be installed on flat roofs with a maximum pitch of 30°.
The Gorter combination of roof hatch and Large scissor stair provides generous access to the roof and is available for ceiling heights of max. 3,000 or 3,500 mm. The roof hatch has an opening of 700 x 1,400 mm.
Large type: max. ceiling height 3,000 mm
Large H type: max. ceiling height 3,500 mm
Roof hatches combined with a scissor stair are ideal for applications where occasional but also frequent access to the roof is required. When the scissor stair is folded, you always have free space under the hatch.
The new generation RHT roof hatches feature an extremely strong and patented construction. Thanks to several modifications, the roof hatch is even more resistant against unexpected extreme loads, both during construction and in general use.
Improved features and functionalities of the indestructible and sustainable RHT roof hatch:
The Gorter RHT roof hatch has a fully thermally broken curb and cover, and a proven high insulation value of Uw ≤ 0.319 W/(m².K) This minimises the chance of condensation forming and guarantees energy cost savings.
10-year warranty on the roof hatch, 1 year on climbing devices
The Large and Large H scissor stair can be used with an extension of scissor stair to bridge a plenum (= space between suspended ceiling and roof).
Read more about the advantages of Gorter roof hatches here
Certifications:
CE ETA-15/0338
Aboma certified according to EN-ISO 14122-3 for access to Lift Engine Rooms
TÜV NORD certified according to EN 14975:2010, with label ''Baumuster geprüft"
Roof hatch, type RHT1015
Standard opening size: 1000 x 1500 mm (Hinge side = long side)
Weight: 84 kg
Gorter® - completely assembled with:
Performance according to CE (ETA-15/0338):
RHT powder coating:
Outside: powder coated in RAL7047
Inside: powder coated in white RAL 9010 (optional black RAL9004)
Scissor stair, type XL
Casing:
Ceiling height: ........ mm, standard 3000 mm
to be specified from top of floor to bottom of cover.
Option: up to 3500 mm (type XL-H).
Stair:
Projection while opening:
Max. 600 mm at ceiling height 3000 mm (type XL)
Max. 850 mm at ceiling height 3500 mm (type XL-H)
Hardware:
Extension of scissor stair in plenum (option):
The stair can de extended to bridge the distance between ceiling and roof hatch in cases where it is mounted in a suspended ceiling/plenum
Standard Electrical operation - GT35
The Gorter GT35 electrical operation is a solution, which can be fitted on any standard Gorter RHT roof hatch. The two powerful electric motors are always fitted as a pair on both sides of the lid.
Suitable for
Operation and control 230Vac
The Gorter GT35 is a system with two motors and a control unit. The system comes standard with a wireless remote control and a compact control panel. The keypad connected with signal cable can be installed remote from control unit.
Dimensions:
Control unit: 265 x 105 x 40 mm
Keypad: +/- 70 x 50 x 10 mm
Length of signal/power cable motors: 2 m
Electrical installation:
The drives and the wiring must be installed by a certified installer
Operation for a hatch with double lids
Depending on the access door type, the weight of the cover and the application, we can install one or more gear rack drives. These drives are available in 24 Vdc or 230 Vac.
Operation and control 230Vac
This is the simplest system with 1 motor. It can be operated with an integrated or surface-mounted switch, not included.
Operation and control 24Vdc
Operation of one or more drives is controlled by a control box with rectifier that is connected to the electricity network.
Features
Depending on the features we will recommend a suitable control box type.
Emergency hatches and doors:
It is of life importance that an emergency door opens after a break down of the electrical system. For those reasons a control box can be provided with a built-in emergency power pack.
Electrical installation:
The drives and the wiring must be installed by a certified installer.
Extension of types Large and XL
Safety Approval Report(EN-ISO 14122-3) available
Height: ........mm
to be specified from ceiling to roof hatch flange or roof deck.
Stairs:
Material: aluminium
Steps are anti-skid
Size steps: 360 x 140 x 26 mm (types Large)
Size steps: 480 x 140 x 26 mm (type XL)
Steps can be horizontally adjusted
Hardware:
Brackets
More information? Please click Products > Ladders and stairs > Extension of scissor stairs - attic ladder
Documentation:
Roof hatch RHT brochure2.71 MB
Technical Data Sheet - Roof Hatches RHT / RHTEI / RHTX154.82 KB
Technical Data Sheet - Scissor stair116.96 KB
Technical Data Sheet - extension of Scissor stair224.99 KB
Technical Data Sheet - Reset / Calibration GT35 / GT50202.93 KB
Manuals:
User information roof hatches2.30 MB
User information scissor stairs3.30 MB
Drawings:
Acrobat |
AutoCAD .dwg |
Sketchup .skp |
REVIT .rfa |
REVIT
.rvt |
REVIT
.ifc |
|
RHT1015 |
Watch the Revit instruction video
Acrobat |
AutoCAD .dwg |
Sketchup .skp |
REVIT .rfa |
REVIT
.rvt |
REVIT
.ifc |
|
XL 1000 x 1300 mm |
||||||
XL-H 1000 x 1300 mm |
Watch the Revit instruction video
Installation roof hatch on concrete upstand42.61 KB
Installation roof hatch on concrete or steel roof45.29 KB
Installation roof hatch on concrete roof41.13 KB
Installation roof hatch on concrete roof insulated53.77 KB
Certificates:
Declaration of performance CE roof hatch RHT44.71 KB
KOMO Certificate: Roof hatch RHT120.07 KB
TÜV NORD Certificate: Roof hatch with ladder, scissor stairs and fixed stairs413.16 KB
TÜV NORD Certificate: Scissor stairs240.38 KB
Aboma Certificate: Roof hatch with scissor stairs access to a lift engine room67.63 KB
EuroSolid Report: Thermal performance Roof hatch RHT525.05 KB
Peutz Report: Sound insulation roof hatch RHT1.14 MB
Gorter roof hatches with scissor stairs provide practical and safe access to flat roofs for maintenance work or other purposes. The roof hatch can be installed on flat roofs with a maximum slope of 30°.
The Gorter combination of roof hatch and type XL scissor stair was developed in part to reach higher lift machine rooms and utility rooms. The scissor stair is supplied with an Aboma certificate for access to (lift) machine rooms in accordance with EN-ISO 14122-3. The wide stair treads (480 mm) and larger roof hatch with an opening of 1,000 x 1,500 mm simplify taking materials to upper areas/roof.
Roof hatches combined with a scissor stair are ideal for applications where occasional but also frequent access to the roof is required. When the scissor stair is folded, you always have free space under the hatch.
The new generation RHT roof hatches feature an extremely strong and patented construction. Thanks to several modifications, the roof hatch is even more resistant against unexpected extreme loads, both during construction and in general use.
Improved features and functionalities of the indestructible and sustainable RHT roof hatch:
The Gorter RHT roof hatch has a fully thermally broken curb and cover, and a proven high insulation value of Uw ≤ 0.319 W/(m².K) This minimises the chance of condensation forming and guarantees energy cost savings.
10-year warranty on the roof hatch, 1 year on climbing devices
The type XL scissor stair can be used with an extension of scissor stair to bridge a plenum (= space between suspended ceiling and roof).
Read more about the advantages of Gorter roof hatches here
Certifications:
CE ETA-15/0338
Aboma certificate
TÜV NORD certified according to EN 14975:2010, with label ''Baumuster geprüft"
Roof hatch, type RHT7010
Standard opening size: 700 x 1000 mm (Hinge side = long side)
Weight: 56 kg
Gorter® - completely assembled with:
Performance according to CE (ETA-15/0338):
Insulating (EN-ISO10077-2): Uw ≤ 0.32 W/(m².K)
Standard powder coating:
Powder coated in RAL7047 (outside) and RAL9010 (inside).
Scissor stair, type S+
Casing:
Ceiling height ........ mm (max. 3000 mm)
to be specified from top of floor to bottom of cover.
Stair:
Projection while opening:
Max. 500 mm at ceiling height 3000 mm (type S+)
Hardware:
Standard Electrical operation - GT35
The Gorter GT35 electrical operation is a solution, which can be fitted on any standard Gorter RHT roof hatch. The two powerful electric motors are always fitted as a pair on both sides of the lid.
Suitable for
Operation and control 230Vac
The Gorter GT35 is a system with two motors and a control unit. The system comes standard with a wireless remote control and a compact control panel. The keypad connected with signal cable can be installed remote from control unit.
Dimensions:
Control unit: 265 x 105 x 40 mm
Keypad: +/- 70 x 50 x 10 mm
Length of signal/power cable motors: 2 m
Electrical installation:
The drives and the wiring must be installed by a certified installer
Operation for a hatch with double lids
Depending on the access door type, the weight of the cover and the application, we can install one or more gear rack drives. These drives are available in 24 Vdc or 230 Vac.
Operation and control 230Vac
This is the simplest system with 1 motor. It can be operated with an integrated or surface-mounted switch, not included.
Operation and control 24Vdc
Operation of one or more drives is controlled by a control box with rectifier that is connected to the electricity network.
Features
Depending on the features we will recommend a suitable control box type.
Emergency hatches and doors:
It is of life importance that an emergency door opens after a break down of the electrical system. For those reasons a control box can be provided with a built-in emergency power pack.
Electrical installation:
The drives and the wiring must be installed by a certified installer.
Technical Data Sheet - Roof Hatches RHT / RHTEI / RHTX154.82 KB
Technical Data Sheet - Scissor stair116.96 KB
Technical Data Sheet - Reset / Calibration GT35 / GT50202.93 KB
Manuals:
User information roof hatches2.30 MB
User information scissor stairs3.30 MB
Drawings:
Acrobat |
AutoCAD .dwg |
Sketchup .skp |
REVIT .rfa |
REVIT
.rvt |
REVIT
.ifc |
|
RHT7010 |
Watch the Revit instruction video
Acrobat |
AutoCAD .dwg |
Sketchup .skp |
REVIT .rfa |
REVIT
.rvt |
REVIT
.ifc |
|
S+ 700 x 1000 mm |
Watch the Revit instruction video
Installation roof hatch on concrete upstand42.61 KB
Installation roof hatch on concrete or steel roof45.29 KB
Installation roof hatch on concrete roof41.13 KB
Installation roof hatch on concrete roof insulated53.77 KB
Certificates:
Declaration of performance CE roof hatch RHT44.71 KB
KOMO Certificate: Roof hatch RHT120.07 KB
TÜV NORD Certificate: Roof hatch with ladder, scissor stairs and fixed stairs413.16 KB
TÜV NORD Certificate: Scissor stairs240.38 KB
Aboma Certificate: Roof hatch with scissor stairs70.66 KB
EuroSolid Report: Thermal performance Roof hatch RHT525.05 KB
Peutz Report: Sound insulation roof hatch RHT1.14 MB
{rsformgt 40 products='Roof hatch',roof-hatches='RHT',ladders-and-stairs='Scissor stairs',type-scissor-stairs='Standard',rht-scissor-stairs='RHT7010: 700 x 1000 mm'}
Gorter roof hatches with scissor stairs provide practical and safe access to flat roofs for maintenance work or other purposes. The roof hatch can be installed on flat roofs with a maximum pitch of 30°.
The Gorter combination of roof hatch and S+ scissor stair is ideal for use in small spaces with a maximum ceiling height of 3,000 mm. The scissor stair folds out to 500 mm, while the roof hatch has a compact clearance of 700 x 1000 mm.
Roof hatches combined with a scissor stair are ideal for applications where occasional but also frequent access to the roof is required. When the scissor stair is folded, you always have free space under the hatch.
The new generation RHT roof hatches feature an extremely strong and patented construction. Thanks to several modifications, the roof hatch is even more resistant against unexpected extreme loads, both during construction and in general use.
Improved features and functionalities of the indestructible and sustainable RHT roof hatch:
The Gorter RHT roof hatch has a fully thermally broken curb and cover, and a proven high insulation value of Uw ≤ 0.319 W/(m².K) This minimises the chance of condensation forming and guarantees energy cost savings.
10-year warranty on the roof hatch, 1 year on climbing devices
The S+ scissor stair is not suitable for use as an extension of scissor stair to bridge a plenum (= space between suspended ceiling and roof).
Read more about the advantages of Gorter roof hatches here
Certifications:
CE ETA-15/0338
Aboma certificate
TÜV NORD certified according to EN 14975:2010, with label ''Baumuster geprüft"
Roof hatch, type RHT7014
Standard opening size: 700 x 1400 mm (Hinge side = long side)
Weight: 68 kg
Gorter® - completely assembled with:
Performance according to CE (ETA-15/0338):
Insulating (EN-ISO10077-2): Uw ≤ 0.32 W/(m².K)
RHT powder coating:
Outside: powder coated in RAL7047
Inside: powder coated in white RAL 9010 (optional black RAL9004)
Electric scissor stair, type Large
Completely assembled Gorter electric scissor stairs
Casing:
Ceiling height: ........ mm, standard 3000 mm.
to be specified from top of floor to bottom of cover.
Stair:
Projection while opening:
Max. 700 mm at ceiling height 3000 mm (type Large)
Max. 950 mm at ceiling height 3500 mm (type Large-H)
Electric operation:
A powerful motor drives the Gorter electric scissor stairs. The system comes with a control unit and a wireless RF remote control as standard.
Hardware:
Standard Electrical operation - GT35
The Gorter GT35 electrical operation is a solution, which can be fitted on any standard Gorter RHT roof hatch. The two powerful electric motors are always fitted as a pair on both sides of the lid.
Suitable for
Operation and control 230Vac
The Gorter GT35 is a system with two motors and a control unit. The system comes standard with a wireless remote control and a compact control panel. The keypad connected with signal cable can be installed remote from control unit.
Dimensions:
Control unit: 265 x 105 x 40 mm
Keypad: +/- 70 x 50 x 10 mm
Length of signal/power cable motors: 2 m
Electrical installation:
The drives and the wiring must be installed by a certified installer
Operation for a hatch with double lids
Depending on the access door type, the weight of the cover and the application, we can install one or more gear rack drives. These drives are available in 24 Vdc or 230 Vac.
Operation and control 230Vac
This is the simplest system with 1 motor. It can be operated with an integrated or surface-mounted switch, not included.
Operation and control 24Vdc
Operation of one or more drives is controlled by a control box with rectifier that is connected to the electricity network.
Features
Depending on the features we will recommend a suitable control box type.
Emergency hatches and doors:
It is of life importance that an emergency door opens after a break down of the electrical system. For those reasons a control box can be provided with a built-in emergency power pack.
Electrical installation:
The drives and the wiring must be installed by a certified installer.
Technical Data Sheet - Roof Hatches RHT / RHTEI / RHTX154.82 KB
Technical Data Sheet - Scissor stair116.96 KB
Technical Data Sheet - Reset / Calibration GT35 / GT50202.93 KB
Manuals:
User information roof hatches2.30 MB
User information scissor stairs3.30 MB
Drawings:
Acrobat |
AutoCAD .dwg |
Sketchup .skp |
REVIT .rfa |
REVIT
.rvt |
REVIT
.ifc |
|
RHT7014 |
Watch the Revit instruction video
Acrobat |
AutoCAD .dwg |
Sketchup .skp |
REVIT .rfa |
REVIT
.rvt |
REVIT
.ifc |
|
Large electric 700 x 1200 mm |
||||||
Large-H electric 700 x 1200 mm |
Watch the Revit instruction video
Installation roof hatch on concrete upstand42.61 KB
Installation roof hatch on concrete or steel roof45.29 KB
Installation roof hatch on concrete roof41.13 KB
Installation roof hatch on concrete roof insulated53.77 KB
Certificates:
Declaration of performance CE roof hatch RHT44.71 KB
KOMO Certificate: Roof hatch RHT120.07 KB
TÜV NORD Certificate: Roof hatch with ladder, scissor stairs and fixed stairs413.16 KB
TÜV NORD Certificate: Scissor stairs240.38 KB
Aboma Certificate: Roof hatch with scissor stairs70.66 KB
EuroSolid Report: Thermal performance Roof hatch RHT525.05 KB
Peutz Report: Sound insulation roof hatch RHT1.14 MB
{rsformgt 40 products='Roof hatch',roof-hatches='RHT',ladders-and-stairs='Scissor stairs',type-scissor-stairs='Electric,rht-electric-scissor-stairs-l='RHT7014: 700 x 1400 mm'}
Gorter roof hatches with scissor stairs provide practical and safe access to flat roofs for maintenance work or other purposes. The roof hatch can be installed on flat roofs with a maximum pitch of 30°.
The Gorter combination of roof hatch and Large Electric scissor stair provides generous access to the roof and is available for ceiling heights of max. 3,000 or 3,500 mm. The roof hatch has an opening of 700 x 1,400 mm.
Large type: max. ceiling height 3,000 mm
Large H type: max. ceiling height 3,500 mm
A powerful motor drives the Gorter electric scissor stairs. The system comes with a control unit and a wireless RF remote control as standard.
Roof hatches combined with an electric scissor stair are ideal for applications where occasional but also frequent access to the roof is required. When the scissor stair is folded, you always have free space under the hatch.
The new generation RHT roof hatches feature an extremely strong and patented construction. Thanks to several modifications, the roof hatch is even more resistant against unexpected extreme loads, both during construction and in general use.
Improved features and functionalities of the indestructible and sustainable RHT roof hatch:
The Gorter RHT roof hatch has a fully thermally broken curb and cover, and a proven high insulation value of Uw ≤ 0.319 W/(m².K) This minimises the chance of condensation forming and guarantees energy cost savings.
10-year warranty on the roof hatch, 1 year on climbing devices
Unlike the standard Large scissor stair, the Large electric scissor stair cannot be used with an extension of scissor stair to bridge a plenum (= space between suspended ceiling and roof).
Read more about the advantages of Gorter roof hatches here
+